WikiLine

A319

Line

26

Smoke Det Fault

all L_ and UA and BK-BL-BN-BM

System malfunction or ECAM Alert



open CB
49VU C06 AIR COND/SDCU/CHAN1
122VU T18 AIR COND/SDCU/CHAN2



After 10 sec close at the same time
49VU C06 AIR COND/SDCU/CHAN1
122VU T18 AIR COND/SDCU/CHAN2



Reset Procedure acc.
TSM-24-00-00-868-061-A



if Fault continues, open CB
49VU C06 AIR COND/SDCU/CHAN1
122VU T18 AIR COND/SDCU/CHAN2
after 20 minutes close CB



After 1 Minutes, start subsequent Test



SDCU Double Channel Fault
TSM-26-17-00-813-803-A

all others

System malfunction or ECAM Alert



open CB
49VU C05 AIR COND/CIDS/SDF/DIR1 ESS
49VU C06 AIR COND/CIDS/SDF/DIR2 ESS
122VU T17 AIR COND/CIDS/SDF/DIR NORM/1
122VU T18 AIR COND/CIDS/SDF/DIR NORM/2



After 10 seconds, close at the same time
49VU C05 AIR COND/CIDS/SDF/DIR1 ESS
49VU C06 AIR COND/CIDS/SDF/DIR2 ESS
and in less than 2 seconds, close at the same time
122VU T17 AIR COND/CIDS/SDF/DIR NORM/1
122VU T18 AIR COND/CIDS/SDF/DIR NORM/2



After CIDS reset, approximately 4 minutes are necessary before recovering normal operation



Reset Procedure acc.
TSM-24-00-00-868-061-B